Product Description
Product image | Type | Description |
---|---|---|
![]() |
UCAM-60 Series Data Logger |
· High resolution 0.1μm/m, max measuring channels 1000 · All-in-one static strain Data Logger UCAM-60B · Online static Data Logger UCAM-65B |
![]() |
UCAM-550A Series Fast Data Logger |
· All channels simultaneous sampling · Synchronously sample at 50 Hz for 1000 channels · 5 kinds of measuring units available |
![]() |
NTB-500A Series Medium Speed Network Terminal Box |
· CAN interface · Large elongation of 300 k μm/m measurement · Strain, voltage, and thermocouple measuring units are available |
![]() |
NTB-100/200 Series Network Terminal Box |
· CAN data output and one cable connection · Digitized data transmission thereby strong against noise · Compact & lightweight, so easy to install on site |
![]() |
SME Series Handy Data Logger |
· Built-in bridge box for easy to connection strain gages · Wide measuring range ±300 k μm/m · Power supply AA batteries |
![]() |
EDT-200B Web Data Logger |
· For UCAM-60 series · Enables users to set observation conditions, show waveforms or download CSV data on the exclusive website · Adopt the packet communication method, thereby enabling data transmission from almost all areas in Japan. |
![]() |
EDT-210B Web Data Logger |
· Directly connect 16 channels of sensor possible · Enable users to set observation conditions, show waveforms or download CSV data on the exclusive website · Adopt the packet communication method, thereby enabling data transmission from almost all areas in Japan. |
![]() |
PCD-430A Sensor Interface |
· Input signals of strain or voltage can be selected channel by channel · Synchronous sampling in 4 units connected by an optional Connection Connector Set · TEDS compliant if Input Adapter UI-10A or UI-11A is used · Max sampling frequency 10 kHz |
![]() |
PCD-400A Sensor Interface |
· Synchronous sampling in 4 units connected by an option Connection Connector Set · TEDS compliant when using Input Adapter UI-10A or UI-11A · Max sampling frequency 10 kHz |
![]() |
EDS-400A Compact Recorder |
· Total 32 channels measurement possible by connecting 8 units · Synchronous sampling up to 20 kHz for 4 channels · Suitable for on-vehicle test · LAN interface |
![]() |
EDX-10 Series Compact Recording System |
· Compact & lightweight · With stacked connection, no synchronization cable is required, therefore wiring-saving. · Synchronous sampling up to 20 kHz for 4 channels · Sensors can be easily connected with input cables or input adapters. |
![]() |
EDX-100A Universal Recorder |
· Models of 1 slot, 2 slots, and 4 slots are available · LAN port for establishing multichannel network up to 256 channels · High-speed sampling at 100 kHz (10 kHz for 16-channel) · Decentralized arrangement with Synchronous Extension Units ESYN-30A is possible |
![]() |
EDX-200A Universal Recorder |
· High-speed/low-speed dual sampling Measurement of high-speed and low-speed phenomena while reducing data quantities is possible. · Built-in real-time digital filters 8th digital filters enable to acquire clear waveform · All channels synchronous sampling at 10 kHz for 32 channels (100 kHz for 3 channels) · EDX-200A-4T can operate under high or low temperature range -20 to 65ºC · One-wire synchronous (Except EDX-200A-1) Up to 8 units in decentralized arrangement for large-scale measurement is possible. |
![]() |
EDX-2000B Memory Recorder/Analyzer |
· Max. synchronous sampling frequency 200 kHz for 16 channels · Built-in large capacity hard disk enables recording of approximately 43 hours of data sampled at 10 kHz in 32 channels. · While acquisition data, analysis processing, input data monitoring and analysis result can be confirmed on the screen · Built-in battery to safeguard against instantaneous power failure |
![]() |
EDX-3000B Memory Recorder/Analyzer |
· High-speed sampling at 200 kHz for 32 channels · Simultaneously record video and other data · Adding options display as all-in-one equipment · Confirmation of status from LED lamps · Online remote control of multiple units |
![]() |
EDX Series Conditioner Cards |
· Conditioner cards for EDX-100A, EDX-200A, EDX-2000A/B, and EDX-3000A/B |
![]() |
Measuring Cards for Optional Slot of EDX-200A-2H/4H |
· Optional cards for EDX-200A-2H/4H/4T · Measurement of CAN data and GPS information · With 8-bit digital I/O |
![]() |
EDB-41B EDX-100A/200A Instantaneous stop battery unit |
Supply power against instantaneous power failure, thereby enabling continuous data acquisition without interruption. |
![]() |
MCA-200A Combined G-resistant Data Logger |
· Shock resistant 196m/s2 (20G) or more · Applicable for measurement of static and dynamic phenomena alternately · A/D converter 16 bits · Max. sampling frequency is 100 kHz for 1 channel each unit, and synchronous sampling at 5 kHz for 128 channels |
![]() |
RMH-301B Digital Strain Recorder |
· Suitable for long-term measurement in the absence of personnel under the environment without external power supply · Compact & lightweight 1-channel model · Equipped with a display used to confirm setting conditions and measured values · Easy to collect data via USB memory |
![]() |
RMH-310A Digital Strain Recorder |
· Suitable for long-term measurement in the absence of personnel under the environment without external power supply · Compact & lightweight 10-channel model · Equipped with a display used to confirm setting conditions and measured values · Easy to collect data via USB memory |
![]() |
SGI-100A Strain Gage Amplifier for Lecture |
· Strain Gage Amplifier for lectures · With a digital display and voltage output · Limited distribution on e-shop Kyowa |